Product Details
Customizable frequency range: 20-6000MHz(Max. bandwidth 500MHz)
Advantages:
All-aluminum cavity: all-aluminum cavity in the whole product body, with sandblasted surface and exquisite workmanship.
Reasonable design: years of experience in RF program, independent development with quality assurance.
Sufficient power and stable performance: high-quality materials, stable and reliable product performance, long service life.
High-efficiency frequency sweeping: comes with high-efficiency frequency sweeping interference source, which greatly improves the monitoring sensitivity of the product.
Small-signal control switch: with small-signal control switch, easy to apply and good countermeasure effect.
Applications:
Mainly applicable to airports, public prosecutor's office system, prisons, detention centers, drug rehab centers, security agencies, troops, large events, concerts, important meetings, government agencies, the need for space confidentiality, anti-drone area.
1. RF specs
Item | Parameter | Remarks |
Operating Frequency | 2400-2500MHz |
|
Operating Voltage | 28V | 24-30V |
Operating Current | <6.5A | 50W @typical |
Controllable output power | 20W~50W | Software set power level |
ALC power adjustment range | ≥10dB | Voltage Controlled Attenuation |
In-band fluctuation | ≤2.5dB | peak-to-peak |
Maximum allowable input power | ≤+10dBm | Lasts 1min without damage |
Input and Output VSWR | ≤1.5 | Add +28V, standard network output -10dBm |
Working temperature | -25℃~+85℃ | Low temperature can start, monitoring works normally |
Power supply and monitoring interface 7W2 Male, RS485 | A1: 28V, A2: GND; Control Pin 1: 485A, 2: 485B; 345 pin: NC |
RF output connector | N-F connector |
LCD liquid crystal display | Display frequency, power, switch status |
with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; |
Outlook dimension | 156 x 122x 58mm |
Weight | 1.6Kg |
Appearance (how to use) | Black integrated module with cooling fan (single or portable use) |
1. Module software settings
Monitoring | Function Description | Remarks |
Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off |
|
Alarm switch | Enable and disable the alarm function |
|
Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥10dB, and the high, medium and low power levels can be set |
|
Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, when the power amplifier temperature exceeds 85℃, it will automatically shut down; 65℃ will automatically restore |
|
Amplifier overpower alarm | The amplifier will shutdown when the actual power value is 2dB higher than the downlink ALC start control threshold |
|
Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier will automatically shutdown |
|
Amplifier over current alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier will automatically shutdown |
|
Amplifier under-power alarm | When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed |
|
Amplifier over or under voltage alarm | When the power amplifier voltage exceeds 32V or under 20V, the power amplifier will automatically shutdown |
|
Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to "OFF", the query should be amplifier OFF status; otherwise, the amplifier will be ON status. |
|
Downlink VSWR value | VSWR is normally 1.2, when the load is mismatched, the query value is 4.0 |
|
temperature query | Detect the internal temperature of the module, detection range: -40℃~+100℃ | Detection error:±3℃ |
Voltage and Current Detection | Detecting module working voltage, operating current and alarm |
|
Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is up to 500MHz, highest frequency is up to 6G. |
Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step-in can be set |
Frequency setting mode 3 | Set any 4 sub-bands within the bandwidth, and a single sub-band needs to be incremented |
Module communication | RS485 |
|
Interface definition | +: 28V,-: GND; control bit 1: 485A,2: 485B |
|